IMMUNOASSAY KITS
|
|
ADGEN IDENTIKIT
TM
Detection of
viruses
,
bacteria
and
fungi
.
96-well strip plate format (12 x 8 wells). Precoated with antibody for das, tas and FAb2 ELISA protocols
-
Antibody probe (tas, pta and FAb2 ELISA)
-
Extraction, antibody probe, conjugate and wash buffers
-
Specific antibody or anti-species alkaline phosphatase conjugate ready to use
-
Positive and negative reaction controls
- ADGEN YELLOW liquid pNPP (A405) or ADGEN BLUE liquid high performance substrate (A595-650) ready to use
|
|
IDENTIKIT-Q
TM
Fully quantitative analysis for selected key pathogens.
|
|
SPOTCHECK LF
TM
the rapid field test which produces a result in 2 minutes
User Guide
-
Remove a piece of leaf which shows suspect symptons.
-
Unscrew dropper from extraction bottle and place plant sample inside. Replace cap and screw on tightly - Shake bottle vigorously for 20 seconds.
-
Remove lateral flow device from foil pouch. Squeeze 2 drops of extract onto sample well on lateral flow device.
-
Wait until blue control line appears and then read result (about 2 minutes). control line plus blue line at test window - positive test. Control line only - negative result.
|
|
ALERT
TM
On-site detection of Phytophthora, Pythium and Rhizoctonia in
15 minutes.
ALERT - Summary User Guide
-
Collect samples and grind with Extrak pads (provided).
-
Insert Extrak strips in extraction solution in bottle 1. Shake 20 times.
-
Break off 3 od antibody pre-coated microtitre wells. Place in well holder.
-
Add 3 drops positive control to first well, 3 drops negative control to second well and 3 drops sample to third well. Incubate 5 minutes.
-
Empty wells and wash 5 times with water using wash bottle provided.
-
Add 3 drops of antibody + conjugate to each well. Incubate 5 minutes.
-
Repeat step 5.
-
Add 3 drops of substrate to all wells. Incubate 5 minutes. Do not wash out wells.
-
Add 3 drops Red Stop Solution and shake gently to mix.
-
Read result visually by comparing sample well colour with positive and negative well colours
|
|
ADGEN FLUORISCAN IF
TM
Detection of bacteria by imunofluorescence.
ADGEN FLUORISCAN IF - User Guide
-
Extract sample by grinding plant tissue in buffer.
-
Shake positive and negative controls to resuspend cells.
-
Place 20μl drop of sample extract to one well on slide provided. Repeat for each control.
-
Add 20μl acetone to each drop. Leave 30 minutes. This fixes bacteria to slide.
-
Wash slide with buffer (PBS).
-
Add 20μl of specific antibody diluted as recommended to each spot on slide. Leave 30 minutes.
-
Wash slide with buffer (PBS).
-
Add 20μl of FITC antibody diluted as recommended to each spot on slide. Leave 30 minutes.
-
Wash slide with buffer (PBS).
-
Mount slide in buffered glycerol and examine under UV microscope.
|
|
AGRISCREEN
TM
Lab detection of Phytophthora, Pythium and Rhizoctonia
AGRISCREEN - For the detection of fungal pathogens
Fungal detection laboratory kit. Results in just 60-90 minutes.
-
96-well strip plate format (12 x 8 wells). Precoated plate.
-
All required buffers and substrate
-
Positive and negative reaction controls
-
User protocol
-
Test time : 60-90 minutes
-
Shelf life 12 months at 4ー-6ーC
Availiable to detect Phytophthora, Pythium, Rhizoctonia and Sclerotinia
|
|
SPOTCHECK
TM
On-site detection of viruses in 15 minutes.
Improving the delivery of your diagnostic system"
These rapid test kits are suited for both laboratory and field use. Simple to use and producing a clear result within 15-20 minutes - no previous experience of laboratory techniques required.
SPOT CHECK - User Guide
-
1. Grind plant tissue in disposable grinder provided.
-
2. Attatch test tip to syringe provided.
-
3. Draw extract into test tip and expel 5 times. Incubate for 5 minutes.
-
4. Expel sap from test tip.
-
5. Draw into test tip liquid from well 1 in test tray. Incubate for 5 minutes.
-
6. Expel liquid from test tip.
-
7. Repeat 4 & 5 with liquid from well 2 in test tray.
-
8. Draw liquid from well 3 in test tray through test tip and into syringe. Do not expel.
-
9. Draw liquid from well 4 in test tray into test tip. Incubate for 5 minutes.
-
10. Stop reaction by expelling contents of syringe through test tip.
-
11. Examine tip for colour development. Colour present - positive test. No colour - negative test.
Full protocol provided with kits
|
|
ADGEN EXPRESS
TM
Bacterial detection in 60 seconds.
このキットは、Fieldで使用することができ、原則的には1分以内で結果が判別できるようデザインされています。基本的には、ブドウ状球菌に抗体を固定した凝集法を取り入れています。この方法ですと、安価であって、目に見えて即座に検出ができます。
|
|
GMOs
・Bt-ENDOTOXIN Quicksti
(R)
・Bt-ENDOTOXIN 96-well plate
|
|